Skip to product information
1 of 1

Iveco

ESE 145 TI

ESE 145 TI

Diesel generator ESE 145 TI

Engine manufacturer
Iveco
Fuel
Diesel
Amperage
190
Power (kVA)
145 / 130
Power (kW)
116 / 105




Technical details

The ESE 145 TI diesel generator produced by Endress Group Romania under the Zenessis brand is equipped with IVECO NEF67TM2A engine, Marelli MXB-E 225 MB4 / Strathon ECO 145 KW alternator and ComAp Inteli Lite AMF 25 control system, which ensures the starting of the generator, the control of the parameters, in manual or automatic system. The generator can be supplied with remote control and monitoring as well as other options. Zenessis power generators are guaranteed for 36 months, up to 2000 operating hours.

Standard features

Command & control panel with measurement & metal control devices, protection class IP54
Static battery charger
Dynamic battery charging alternator
Controlled thermostat heater for coolant
Oversized start battery
Emergency stop button
Chassis with fuel tank sized for 8hrs of autonomy
Vibration dampers
Fuel level measuring device
Electrical lines protected with tubing & gland
Residential silencer
Access doors on all 4 sides provided with locks
Crane or forklift handling system
Flameproof and soundproof insulation
Protective pads
Metal hinges

Iveco diesel engine

Engine

Model IVECO
Model NEF67TM2A
No. of cilinders & arrangement 6 in linie
Cooling system With liquid (water + 50 % paraffin 11)
Induction system Turbo, secondary air/air coo
Injection system Direct
Standby power (kWm) 126 KWh
Speed (rpm) 1500 rpm
Displacement (l) 6,7 (I)
Bore & Stroke (mm) 104 x 132 mm
Compression factor 17,5 : 1
Regulator Mechanic
Total oil capacity (l) 17,2 (I)
Engine/radiator coolant capacity & hoses 25,5 (l)
Fuel consumption at 100% load (l / h) 29,3 (l / h)

Standard features

Alternator Marelli/Strathon

Model MXB-E 225 MB4 / ECO 145 KW
Frequency (Hz) 50 Hz
Concept Brushless, 4 poles
Power factor 0.8
Phases 3
Voltage (V) 400 / 230 V
Excitation system Electronic
Performance 93%
Protection IP23
Certification test test EN 10204:2001

Control panel

Made in metal box, IP54 degree, with lock. The control panel is equipped with the ComAp AMF25 control module, with the possibility of starting and stopping the generator, both in automatic and in electric mode. The control panel monitors the power grid and can command and control the ATS panel (automatic transfer switch).

Control panel standard specifications :

The command and control panel is mounted inside the casing, in a metal box with IP 54, equipped with a viewing glass, equipped with:

ComAp AMF 25 command module
Static battery charger
Emergency stop button & circuit breaker fuses control
Overcurrent differential protection
Protection relays

Control panel

1. Left button
2. Right button
3. Horn Reset button
4. Fault Reset button
5. Up button
6. Page button
7. 7. Down button
8. Enter button
9. Start button
10. Stop button
11. GCB button. Works in MAN and TEST modes only 12. MCB button. Works in MAN and TEST modes only
12. MCB button. 12. MCB button. Works in MAN and TEST modes only
13. Generator status indicator
14. GCB On. Green LEDs are on if GCB is closed and Gen-set is healthy
15. Load
16. Graphic B/W display, 132 x 64 pixeli
17. Mains status indicator
18. MCB On. The green LEDs are “on” when the MCB is closed and the network is within the preset parameters.

Command module standard specifications:

Microprocessor control
132 x 64 pixeli LCD display
Programming on front panel as well as through PC software
Control buttons and soft touch navigation
Remote communication via USB or with optional modules via RS232, RS485, Ethernet or SMS
Store 180 events with date and time
Maintenance programming 3 levels
Engine heater control –Optional

Configuration

Configuration

1. ComAp AMF25 command module
2. Circuit Breaker protection
3. Locks
4. Alarm
5. START button ON / OFF
6. Hinges
7. Maintenance schedule
8. Metal box

Displays:

Engine – engine speed; oil pressure; coolant temperature; running time; battery voltage; maintenance data.
Alternator – voltage (L – L, L – N); current (L1 – L2 – L3); frequency; kW; Pf; kVAr; kWh,kVAh, kVarh; phase sequence.
Main network – voltage (L – L, L – N); frequency, mains ready; mains off; generator set ready, generator set disconnected, active power kW, apparent power kVA, reactive power kVA r, power factor, phase sequence.
Warning – battery faulty charging, low battery voltage, fail to stop, low fuel level, overload, phase reversing, speed sensor failure.
Alarms – low oil pressure, high engine temperature, under / over voltage, under / overfrequency, under / overvoltage, ECU fault -optional.
Status displays – missed start, emergency stop, low oil pressure, high engine temperature, under / overspeed, under / overfrequency, under / overvoltage, oil sensor, phase rotation, overload, overcurrent group, phase reversal.

Static battery charger:

Made with TSD technology, with high efficiency. Protected for short- circuit currents, it can be used as a current source, input voltage 196-264 V, output voltage 27.6 V / 5A or 13.8 V / 5A.

Standards

Electrical safety / EMC, BS EN 60950; BS EN 60950 – 6 – 2 EMC; BS EN 61000 – 6 – 4 EMC.

Housing

Made of galvanized steel, painted in electrostatic field, soundproofed. It is modularly designed with in-door access doors on all sides of the generator. The exhaust pan is residential type, mounted inside the casing. The enclosures are designed to optimise cooling of the engine and alternator assembly and can be mounted outdoors, providing weather protection and low noise.

Housing

1. Command module
2. View window
3. Access door for control module
4. Points for crane lifting (optional)
5. Spaces for handling with the forklift
6. Usa acces motor si alternato
7. Air intake grills
8. Handles provided with locks
9. Fuel supply bus (optional)
10. „Sleigh chassis” fitted with lifting/pulling holes
11. Emergency button
12. Exhaust Gas Valve
13. Cable access space
14. Hot air outlet grills
15. Protective pads

Dimensions and weight

Dimensions and weight of open genset

Sizes (length x width x height) (mm) 3189 x 1174 x 1620
Weight (kg) 1600
Fuel tank capacity (liters) 250

Dimensions and weight of the closed genset

Sizes (length x width x height) (mm) 3189 x 1174 x 1950
Weight (kg) 1920
Fuel tank capacity (liters) 250

Optional features

Electrical panel anti-condensation heating system
Fuel / oil heating system
Coolant heating circulation pump
Oil drain pump
Remote monitoring & control system
AAR transfer panel with 3/4 poles
3/4 pole differential protection
Sokets 400 V/ 230 V
Fuel filter with water detection
Bypass panel – ENDRESS patented invention – OSIM patent 00010 / 2012
Trailer
Start by remote control
Groundless protection
Interior lightings with switches operated at doors opening
Liquid retention tray
Liquid leakage detection sensor
Motorized ATS, ENDRESS patented invention – OSIM patent 00048 / 2015
Exterior fuel filler cap with lock
Pocket system integrated in the chassis for lifting with forklift
Fire extinguisher with internal housing support
Super soundproof housing
Intake air heating spark plug
Grounding electrodes
Fuel transfer automatic pump
Mobile distribution panel with 4 sockets
Cable reel
Fire detector with automatic shutdown generator set
Fire extinguishing system with inert gas
View full details